X25AM Configuration and Management Manual

Attribute Descriptions
X25AM Configuration and Management Manual523424-004
5-3
CALLS
CALLS
declares whether calls cannot be connected (NONE), can be initiated by a DTE
(OUTGOING), can be received by a DTE (INCOMING) or can be initiated and received
by a DTE (TWOWAY).
CHARACTERSET
This attribute is not supported for systems running G-series or H-series RVUs.
CLOCKMODE
sets the mode of the clock.
DCE disables the communications line interface processor (CLIP) clock; no internal
clock is generated.
DTE enables the CLIP clock; an internal clock is generated and made available on the
interface clock pins. Use DTE if your system uses the clock from the DTE rather than
the clock generated by the DCE (or if the DCE clock is not available) as in the case of
a modem eliminator.
CLOCKSPEED CLOCKnnnn
sets the speed of the line.
CPADPARMS
specifies the conversational-mode X.3 PAD parameters. You must specify the value as
pairs of integers (the parameter number and its value). This attribute is valid only if the
PROTOCOL attribute value is ITI. If you do not specify the SU’s CPADPARMS, SCF
Default: TWOWAY
Range: NONE, OUTGOING, INCOMING, or TWOWAY
Objects: Lines
Default: DTE
Range: DCE, DTE
Objects: Lines
Default: 600 (no leading 0)
Range: 600, 1200, 2400, 4800, 9600, 19200, 38400, 56000, 115200
Objects: Lines
Caution. It is recommended that you do not set CLOCKSPEED greater than the maximum
speed of 19200 BAUD when using an RS232 interface; speeds over 19200 BAUD can cause
line or frame errors