X25AM Configuration and Management Manual

PTrace for the X25AM Subsystem
X25AM Configuration and Management Manual523424-004
6-28
Common X.25 Terms
Operation
X25AM
Parameter
Probable
Value Meaning
Device Modifier/
Line Attribute
Name
Restart T20 180
seconds
Timer set at DTE issue
of restart request.
Txx
Call request T21 200
seconds
Timer set at DTE issue
of call request.
Txx
Reset T22 180
seconds
Timer set at DTE issue
of reset request.
Txx
Clear T23 180
seconds
Timer set at DTE issue
of clear request.
Txx
Restart R10 1 retry Number of restart
requests sent before T10
times out.
Rxx
Call request R11 0 retry No retries allowed. Call
is cleared.
Rxx
Reset R12 1 retry Number of reset
requests sent before T12
times out.
Rxx
Clear R13 1 retry Number of clear
requests sent before T13
times out.
Rxx
Restart R20 1 retry Number of restart
requests sent before T20
times out.
Rxx
Call request R21 0 retry No retries allowed. Call
is cleared.
Rxx
Reset R22 1 retry Number of reset
requests sent before T22
times out.
Rxx
Clear R23 1 retry Number of clear
requests sent before T23
times out.
Rxx
Table 6-5. X.25 Configuration Parameters and X25AM I/O Process Modifiers