X25AM Configuration and Management Manual

Configuring an X25AM Subsystem
X25AM Configuration and Management Manual523424-004
3-13
List of X25AM I/O Process Modifiers
CLBWINDOWNEXT Not in effect
CLOCKnnnn 600 nnnn is the speed
DCECLOCK or DTECLOCK DCECLOCK
DRTIMEOUT 300 (3 seconds) --
DSRTIMER 2000 (20 sec.)
DTE or DCE DTE --
EMSFORCLEAR or
NOEMSFORCLEAR
NOEMSFORCLEAR
EMSFORFRMR Zero Configured with a
non-zero value to enable
EMS message generation
when a link reset occurs
due to an FRMR (Frame
Reject) condition.
ENABLECALLEDADDREXT Not set Applies only to Call
Address Extension facility
users.
ENABLEPVCOUTOFORDER
or
DISABLEPVCOUTOFORDER
ENABLEPVCOUTOFORDER Applies to PVC only.
EXTENDEDPOOLPAGES 50 (pages) Replaces
LOCALPOOLPAGES.
FIFO Not set
IDLERESPRR or
IDLECMDRR
IDLERESPRR --
LINEQUALITYTHRESHOLD 500
L2DOWNLINE or
NOL2DOWNLINE
L2DOWNLINE
L2IDLETIMEOUT 1500
L2IFRAMERECOVERY Not in effect
L2NODISC or L2DISC L2NODISC --
L2RETRIES 10 --
L2TIMEOUT 300 (3 sec.) --
L2WINDOW 4 --
L3MOD8 or L3MOD128 L3MOD8 --
L3RECVTHRUPUT 4 --
Table 3-1. List of X25AM Modifiers and Defaults (page 2 of 4)
Modifier Name
(Default Listed First) Default Setting Notes
-- Not applicable.