Numeric Range Validation
DTECLOCK. See DCECLOCK
EBCDIC. See ASCII
EMSFORCLEAR
When EMSFORCLEAR is set, X25AM generates a clear message to indicate that a
connection has been cleared with either a diagnostic code or any cause code other
than zero. When the default, NOEMSFORCLEAR, is set, X25AM does not generate a
message.
EMSFORFRMR
EMSFORFRMR is configured with a non-zero value to enable generation of the EMS
message when a link reset occurs due to an FRMR condition on an X25AM line. An
FRMR condition occurs when an illegal frame is received on an X25AM line.
Figure 3-6. DTE and DCE Functions
Default: NOEMSFORCLEAR
Units: Not applicable
Alternate Modifier: EMSFORCLEAR
Default: Zero
Units: Not Applicable
Range: 0 to 200
VST0306.vsd
Network
Incoming Call,
Clear Indication,
or Data Packet
Calling
DTE
Called
DTE
Local
DCE
Remote
DCE
Call Request,
Clear Request,
or Data Packet
Call Connected,
DCE Clear Confirm,
Data Packet, or RR
Call Accepted,