X25AM Configuration and Management Manual

Configuring an X25AM Subsystem
X25AM Configuration and Management Manual523424-004
3-22
Numeric Range Validation
(50 * 5095) / 2048
254,750 /2048 = 124.3 Ý 128 + 10 = 135 (less conservative)
EXTFORMAT. See NOEXTFORMAT
FIFO
This modifier allows X25AM to send L3 packets from SUs in the order they are
generated.
If set, X25AM sends the L3 packets in the order the application sends the data.
If not set (reset), X25AM send the L3 packets in the order of the scan (0, 1, ...) of
all SUs on the line.
IDLECMDRR. See IDLERESPRR
IDLERESPRR
IDLECMDRR or IDLERESPRR specifies whether an RR (receiver-ready) command
frame or an RR response frame is sent when an L2IDLETIMEOUT occurs.
IDLERESPRR: Sends an RR response frame. The poll bit is not set; therefore, no
reply is required.
IDLECMDRR: Sends an RR command frame. The poll bit is set; therefore, a reply
is required.
The value that is used depends on the network requirement.
Default Not set
Units: Not applicable
Alternate Modifier: None; use RESET FIFO to reset this modifier
Default: IDLERESPRR
Units: Not applicable
Alternate Modifier: IDLECMDRR