X25AM Configuration and Management Manual

SCF Commands for the X25AM Subsystem
X25AM Configuration and Management Manual523424-004
4-27
Display for the INFO LINE Command
Name
shows the name of the LINE object.
L3Window
shows the number of packets that can be outstanding without an acknowledgment
from the network. The range is 1 through 15.
PacketSize
shows the size, in bytes, of each packet.
Type
shows the LINE object's type and subtype.
Retries
shows the number of level-2 retries (N2) to be attempted before a disconnect. This
value must be in the range 0 through 255.
FrameMode
shows whether this is a DCE or DTE station.
The format of the display for the INFO LINE command with the DETAIL option is:
Blank fields in the display above indicate either that they were never set or that they
have been reset.
X25AM Detail Info LINE $X25AZ1
*CallingAddr.. ON *Threshold.. 500 *CharacterSet. EBCDIC
Debug........ OFF *SYNCS...... 3 *DSRTimeout... 0:20.00
*Extformat.... OFF *L3window... 15 *IdleTimeout.. 0:15.00
*Interface.... RS232 *L3mod...... 128 *PVCrange.....
*Netid........ X25XA *Retries.... 10 *SVCrange..... ( 1,510 )
*CUG.......... *Framemode.. DTE *T1Timeout.... 0:03.00
*CUGType...... BASIC *BCUG....... *Transitdelay.
*Calls........ TWO WAY PacketSize. 512 Type......... (61,63)
*Clockmode.... DCE *Clockspeed. CLOCK600
*SrcAddr......
*Program...... $SYSTEM.CSS02.C1096QF1
*EmsForFrmr... 0
*RPOA..........
*Bpadparms....
*Cpadparms....
Note. In the displays for the INFO command, an asterisk (*) indicates that the value of the
attribute can be changed with the ALTER command.