X25AM Management Programming Manual
Commands and Responses
X25AM Management Programming Manual—528037-001
6-58
DISCONNECT Command
occurrences are not allowed. ZCOM-TKN-OBJNAME is described in Section 5,
Common Definitions.
ZCOM-TKN-CMD-TIMEOUT and ZCOM-MAP-REQID
are standard data communications tokens that are described in the SPI Common
Extensions Manual. Duplicate occurrences of these tokens are not allowed.
(ZSPI-TKN-) MAXRESP, RESPONSE-TYPE, ALLOW-TYPE, and COMMENT
are standard SPI tokens described in the SPI Programming Manual. With the
exception of ZSPI-TKN-COMMENT, duplicate occurrences of these tokens are not
allowed.
Tokens in Response Buffer
ZSPI-TKN-DATALIST
is a standard SPI data list, as described in the SPI Programming Manual. The list
ends with the token ZSPI-TKN-ENDLIST.
ZCOM-TKN-OBJNAME
is an object-name token that contains the name of the subdevice that was
disconnected by the command. If there is no error, this token is present in every
response record. ZCOM-TKN-OBJNAME is described in Section 5, Common
Definitions.
ZCOM-TKN-OBJTYPE
is an object-type token that contains the value ZCOM-OBJ-SU. This token is
present in every response record, and it is described in the SPI Common
Extensions Manual.
ZSPI-TKN-RETCODE
is the standard SPI return token described in the SPI Programming Manual.
Some values of RETCODE that are likely to occur in response to the
DISCONNECT command are the following:
-19 (ZCOM-ERR-OBJNAME-INV) An invalid object name was
present in the command.
-17 (ZCOM-ERR-OBJ-NOT-FOUND): The specified object cannot be
found.
-3 (ZCOM-ERR-CMD-INV-IN-SUMSTATE): The current summary state of the
object prevents processing of the
command.