START Command
ZCOM-TKN-OBJNAME
is an object-name token that indicates which lines and subdevices are to be
started. This token must be present in the command.
If the object type in the command is ZCOM-OBJ-LINE, only one object-name
token, containing the name of a line, can be present in the command (see ZCOM-
TKN-SUB).
If the object type in the command is ZCOM-OBJ-SU, the command can contain as
many object-name tokens as will fit into the command buffer. Each object-name
token contains one subdevice name.
This token is described in Section 5, Common Definitions.
ZCOM-TKN-CMD-TIMEOUT and ZCOM-MAP-REQID
are standard data communications tokens that are described in the SPI Common
Extensions Manual. Duplicate occurrences of these tokens are not allowed.
ZCOM-TKN-SUB
is the subordinate-modifier token, as described in the SPI Common Extensions
Manual. Duplicate occurrences are not allowed. This token can have the following
values:
If this token is not present, the command affects only the named line or
subdevices.
(ZSPI-TKN-) MAXRESP, CONTEXT, RESPONSE-TYPE, ALLOW-TYPE, and
COMMENT
are standard SPI tokens described in the SPI Programming Manual. With the
exception of ZSPI-TKN-COMMENT, duplicate occurrences of these tokens are not
allowed.
ZCOM-VAL-SUB-ALL The named line and all its subordinate subdevices
are to be started.
ZCOM-VAL-SUB-NONE Only the named line or subdevice is to be started.
Any subdevices subordinate to the line or subdevice
are not affected by this command.
ZCOM-VAL-SUB-ONLY Only the subdevices subordinate to the named line
are to be started. The line itself is not affected by this