X25AM Management Programming Manual

Commands and Responses
X25AM Management Programming Manual528037-001
6-131
STATUS Command
and the DDL definition ZX25-DDL-STATUS-LINE. This token contains the following
fields:
ZLDEV
contains the logical device number of the line.
ZIN-USE
indicates whether or not the line is in use. This field can have the following
values:
ZSTATE
indicates the current summary state of the line. This field can have the
following values:
ZLINK-STATE
indicates the current state of the link. This field can have the following values:
ZCKTS
contains the number of circuits specified at system-generation time.
ZCPU
contains the processor number of the processor for the primary X25AM
process.
ZDEV-TYPE
is a pair of integers that contains the type and subtype of the line.
ZPPID
contains the primary process ID of the X25AM subsystem.
ZSPI-VAL-TRUE The line is currently in use.
ZSPI-VAL-FALSE The line is not currently in use.
ZCOM-VAL-SUMSTATE-DIAG The line is in the DIAGNOSING summary
state.
ZCOM-VAL-SUMSTATE-STARTED The line is in the STARTED summary state.
ZCOM-VAL-SUMSTATE-STOPPED The line is in the STOPPED summary state.
1 The link is down.
2 The link is not ready.
3 The link is ready.