X25AM Management Programming Manual

Commands and Responses
X25AM Management Programming Manual528037-001
6-139
STOP Command
ZCOM-TKN-OBJNAME
is an object-name token that contains the name of a line or subdevice that was
terminated by the command. If there is no error, this token is present in every
response record. ZCOM-TKN-OBJNAME is described in Section 5, Common
Definitions.
ZCOM-TKN-OBJTYPE
is an object-type token that indicates the type of the object named in ZCOM-TKN-
OBJNAME. This token can have the following values:
ZCOM-TKN-OBJTYPE
is present in every response record, and it is described in the SPI Common
Extensions Manual.
ZSPI-TKN-RETCODE
is the standard SPI return token described in the SPI Programming Manual.
Some values of RETCODE that are likely to occur in response to the STOP
command are the following:
For command-specific information about these error numbers, see Error-Handling
Notes on page 6-140. For descriptions of all X25AM error numbers, see
Appendix A, Error Numbers and Error Lists.
ZCOM-OBJ-LINE The object is a line.
ZCOM-OBJ-SU The object is a subdevice.
-30 (ZCOM-ERR-TKN-VAL-INV): A supported token had an improper
value.
-25 (ZCOM-ERR-SUB-NOT-FOUND): No subordinate objects were found.
-17 (ZCOM-ERR-OBJ-NOT-FOUND): The specified object cannot be
found.
-16 (ZCOM-ERR-OBJ-ALRDY-IN-
SUMSTATE):
The object is already in the desired
summary state.
-3 (ZCOM-ERR-CMD-INV-IN-SUMSTATE): The current summary state of the
object prevents processing of the
command.
510 (ZX25-ERR-SUBDEV-OPEN): The STOP command is not
completed because the subdevice
is open.
512 (ZX25-ERR-OBJ-NAME-NOT-SUPP): The object name is not supported
by the X25AM subsystem.
4999 (ZX25-ERR-EMPTY-RESPONSE): The empty response record is
being returned.