147: ZX25-EVT-CSS-PROBE-ERROR
If the In Boot bit is equal to 1, the CLIP is operating from the bootstrap, where the
command set is limited.
The Error field typically reports fatal errors; that is, errors that force the CLIP to reenter
the bootstrap from running code.
The Error field can have the following values:
If the value of param3 is -1, there was no response to the status probe and the probe
timed out.
Cause. The 6100 CSM received a status probe response from the CLIP indicating that
it is in the boot state instead of the run state.
Effect. The X25AM subsystem attempts to download the CLIP again. If this cannot be
done on the primary path, X25AM attempts a download on another path.
Recovery. Decode the CLIP status byte given by the value param3 of the text
message to determine which error occurred, and note the error for your HP
representative. If the CLIP does not restart automatically, try to restart it manually.
0 No error
1CLIP PON
2 Deadman timer expired (nonmaskable interrupt)
3 RAM parity error
4 Reset command frame received
5 LIM power fault
6 Instruction failure (SWI2, SWI3, bad jump to trap code)
7 Deadman timer expired (CLIP RESET)
8 through 15 Reserved
16 Buffer pool boundary tag destroyed (kernel detected)
17 CLB task transmit state machine failure
18 CLB task receive state machine failure
19 through 31 Reserved for kernel or CLB errors
32 through 63 Reserved for application-detected failures