X25AM Management Programming Manual

Event Management
X25AM Management Programming Manual528037-001
7-47
152: ZX25-EVT-CSS-CLB-CMD-REJECT
152: ZX25-EVT-CSS-CLB-CMD-REJECT
The Break Out Board (BOB) of the 6100 Communications Subsystem (CSS) was not
properly synchronized with the host. This event is a critical event, and the event
message is reported to the EMS collector, $0.
This event message is equivalent to console message 152.
ZSPI-TKN-SSID
is the X25AM subsystem ID, and its value is ZX25-VAL-SSID. This token is
described in the SPI Programming Manual.
ZEMS-TKN-EVENTNUMBER
is the event number, as described in the EMS Manual. Its value is ZX25-EVT-CSS-
CLB-CMD-REJECT (152).
ZEMS-TKN-SUBJECT-MARK
is the standard EMS token that always immediately precedes the subject token--
here, ZEMS-TKN-LDEVNAME.
ZEMS-TKN-LDEVNAME
is the name of the X25AM line that is the subject of this event message. This token
is described in the EMS Manual.
Tokens
ZSPI-TKN-SSID token-type ZSPI-TYP-SSID.
ZEMS-TKN-EVENTNUMBER token-type ZSPI-TYP-ENUM.
ZEMS-TKN-SUBJECT-MARK token-type ZSPI-TYP-MARK.
ZEMS-TKN-LDEVNAME token-type ZSPI-TYP-FNAME32.
ZEMS-TKN-LDEV token-type ZSPI-TYP-UINT.
ZEMS-TKN-EMPHASIS token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CONSOLE-PRINT token-type ZSPI-TYP-BOOLEAN.
ZEMS-TKN-CPU token-type ZSPI-TYP-UINT.
ZEMS-TKN-CRTPID token-type ZSPI-TYP-CRTPID.
ZEMS-TKN-GENTIME token-type ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-LOGTIME token-type ZSPI-TYP-TIMESTAMP.
ZEMS-TKN-PIN token-type ZSPI-TYP-UINT.
ZEMS-TKN-SYSTEM token-type ZSPI-TYP-UINT.
ZEMS-TKN-USERID token-type ZSPI-TYP-BYTE-PAIR.
Event-Message Text
LDEV ldev [ CU %ccu ] X25: CSS CLB COMMAND REJECT,
CIU path %param3 %param4 %param5 (BELL)