X25AM Management Programming Manual

Error Numbers and Error Lists
X25AM Management Programming Manual528037-001
A-2
510: ZX25-ERR-SUBDEV-OPEN
510: ZX25-ERR-SUBDEV-OPEN
This error number indicates that the STOP command is not completed because the
subdevice is open.
ZSPI-TKN-ERROR
is the standard SPI error token, as described in the SPI Programming Manual. Its
value consists of the X25AM subsystem ID and the error number ZX25-ERR-
ATTR-DUP. This token is always present in the error list.
ZCOM-TKN-OBJNAME
is the object name provided with the command on which the error occurred. This
token is always present in the error list, and it is described in Section 5, Common
Definitions.
ZCOM-TKN-OBJTYPE
is the object type provided with the command on which the error occurred. Its
possible values are ZCOM-OBJ-LINE and ZCOM-OBJ-SU. This token is always
present in the error list, and it is described in the SPI Common Extensions Manual.
Cause. This error number is returned when the STOP command is not completed
because the subdevice is open.
Recovery. Use the ABORT command or close the subdevice and reissue the STOP
command.
ZSPI-TKN-ERRLIST token-type ZSPI-TYP-LIST.
ZSPI-TKN-ERROR token-type ZSPI-TYP-ERROR.
ZCOM-TKN-OBJNAME token-type ZSPI-TYP-STRING.
ZCOM-TKN-OBJTYPE token-type ZSPI-TYP-ENUM.
ZSPI-TKN-ENDLIST token-type ZSPI-TYP-SSCTL.