X25AM Management Programming Manual

Commands and Responses
X25AM Management Programming Manual528037-001
6-34
ALTER LINE Command
ZSYNCS
specifies the number of SYN characters that will be transmitted before each
frame. The value assigned to this field must be in the range 1 through 15. This
field applies only to the 6201 controller, and it corresponds to the SYSGEN
modifier SYNCS.
ZTHRES
specifies the number of frames to be sent and received before line quality is
checked. This field corresponds to the SYSGEN modifier
LINEQUALITYTHRESHOLD.
ZCUG-TYPE
specifies which CUG facility is selected. This field can be assigned the
following values:
If the CUG ID is reset or is not configured, CUGTYPE contains the default
value BASIC.
If the CUG ID is configured to be 99 or less, then the CUGTYPE can be any of
the four values. The default in this case is BASIC.
If the CUG ID is configured to be greater than 99, then the CUGTYPE must be
EXT or EXTOA. The default in this case is EXT.
ZBCUG
specifies the bilateral closed user group ID sent in every call-request packet.
The line BCUG establishes a default value that is used when the subdevice
BCUG attribute is not specified. The range is 0 through 9999.
ZRPOA
specifies the Recognized Private Operating Agency (RPOA) transit network(s)
in the facility field of a call-request packet. The line RPOA establishes a default
value that is used when the subdevice RPOA attribute is not specified. An
RPOA transit network is indicated by the Data Network Identification Code
(DNIC), which is an integer with the range 0 through 9999.
ZRPOA-DNIC-CNT
specifies the number of DNICs listed in the ZRPOA field. The range is 0
through 7.
ZX25-VAL-CUG-TYPE-BASIC Basic format CUG selection
ZX25-VAL-CUG-TYPE-EXT Extended format CUG selection
ZX25-VAL-CUG-TYPE-BASICOA Basic format CUG with outgoing access
selection
ZX25-VAL-CUG-TYPE-EXTOA Extended format CUG with outgoing access
selection