Chapter 6.  EMS Message Format 
Templates 
A template is supplied on the installation subvolume to allow the audit lines written to 
EMS to be tokenized and organized as desired by the customer. Three files are 
supplied at installation to allow this customization. The three files are: 
EMSBUILD  A macro to build the template file based on the system templates 
and the EMSTEMP file. 
EMSDDL  A DDL layout for the EMS message. 
EMSTEMP  The TEMPLATE layout for the XYGATEAC messages. 
6.1  Procedure 
To build a template file that can be used with an EMS distributor such as EMSA, run 
the EMSBUILD macro as follows: 
Example: 
1> VOLUME $SYSTEM.XYGATEAC 
2> RUN EMSBUILD 
You will be asked a series of questions about the installation 
of the XYGATEAC EMS template. You may abort this process at any prompt 
by hitting the BREAK key. 
Prompts that end with a string within angle brackets mean 
that just hitting the return key will use the default value. 
Which volume do you want the XYGATEAC EMS templates installed on 
<$SYSTEM>? $SYSTEM 
Which subvolume do you want the XYGATEAC EMS templates installed on 
<XYGATEAC>? XYGATEEM 
1) $SYSTEM.ZSPIDEF.ZSPIDDL 
2) $DATA4.ZSPIDEF.ZSPIDDL 
Which file do you want to use <1>? 1 
What file contains the EMS template for XYGATEAC 
<$SYSTEM.XYGATEAC.EMSTEMP>? $SYSTEM.XYGATEAC.EMSTEMP 
XYGATEAC EMS volume   : $SYSTEM 
XYGATEAC EMS subvolume  : XYGATEEM 
System resident template  : $SYSTEM.SYS04.RTMPLATE 
New resident template  : $SYSTEM.XYGATEEM.RTMPLATE 
System nonresident template : $SYSTEM.SYS04.TEMPLATE 
New nonresident template  : $SYSTEM.XYGATEEM.TEMPLATE 
XYGATEAC template   : $SYSTEM.XYGATEAC.EMSTEMP 
ZSPIDEF Subvolume   : $SYSTEM.ZSPIDEF 