XYGATE Compliance PRO (XSW) Reference Manual
XYGATE
®
Compliance PRO
™
Reference Manual
Chapter 1. Installing Compliance PRO (XSW)
XYPRO Technology Corporation 11 Proprietary and Confidential
Example:
TACL> RUN \X.$VOL.ZXYPROSW.LICENSES
File Utility Program - T6553H01 - (26APR2010) System \X
(C)1981 Tandem (C)2006 Hewlett Packard Development Company, L.P.
license $VOL.XSW160.USERINFO
license $VOL.XSW160.ACLINFO
license $VOL.XSW160.OSSLIB
secure $VOL.XSW160.xygatesw,,progid
secure $VOL.XSW160.xyswstrt,,progid
Licensing $VOL.XTR156.ADOPT
Licensing $VOL.XTR156.USERINFO
TACL> Logoff as the SUPER.SUPER or SUPER alias.
When you complete the licensing tasks, answer Y to the prompt to continue.
Are you ready to continue <Y/N>? Y
Establishing product locations ...
Product locations established.
Performing verifications ...
Verifications complete.
Installing products:
Install of products complete.
Performing products syntax check ...
Products syntax check complete.
Verifying XSW is listed in XTR TRACL file ...
Done verifying XSW is listed in XTR TRACL file.
XYGATE GUIs use a LISTNER process to connect to the host.
You may choose to have a XYGATE LISTNER started now.
WARNING: The XYGATE LISTNER is intended for testing your XYGATE/TR
configuration. This XYGATE LISTNER process may disappear. To assign
a permanent LISTNER, add the following to $SYSTEM.ZTCPIP.PORTCONF
and restart the HP LISTNER:
The port connection for the GUI/PC modules can be permanently set up to the
system’s PORTCONF file using the following information. If the port is defined in this
manner, it will be restarted each time the system is cold-loaded or TCP/IP is re-started.
1121 $VOL.XTR156.XYGATETR -server
If this is a new install, you will be asked to start the LISTNER process for connection
from the PC/GUI products. Starting the LISTNER is not a requirement for the server
portion of the XSW product. It may be started at anytime. If started now, it will bind
itself to the port number you previously entered in the script.
Would you like to start the XYGATE LISTNER now <Y/N>? Y
The GUI/PC modules will not be able to connect without a LISTNER set up via this
script or via the PORTCONF. Refer to the GUI Product User Guides from XYPRO for