XYGATE Merged Audit Reference Manual

Table Of Contents
XYGATE Merged Audit
®
Reference Manual
Chapter 4. Generating Reports Using XRM
XYPRO Technology Corporation 95 Proprietary and Confidential
4.17 Select by Text in the Result Column
You can limit your data by reporting based on the value in the RESULT column of the
Audit Detail Table.
Selection?p
Enter case-sensitive results separated by commas.
A leading * on a result will match any results that
contain the specified string. A trailing * will match any
results that start with the specified string.
The NOT keyword can be used: <result list> NOT <result list>
Result <*>?
For example, if you would like to eliminate the Safeguard record that notes the change
to a user’s Last Logon Date, you could enter:
* NOT * NOT Last Logon Date
4.18 Select by Message Code
You can limit your data by reporting based on the value in the Message Code column
of the Audit Detail Table.
Q: Message Code :*
4.19 Select by Message ID
You can limit your data by reporting based on the value in the Message ID column of
the Audit Detail Table.
4.20 Run the Report
When you are satisfied with your selections, select Z or ZP to create the report.
Z Generates the report and returns you to the TACL Prompt
ZP Generates the report and opens PERUSE. When you exit PERUSE, the Report
Selection Screen reappears with your previous entries still in place. You may modify
them if you wish to create another report.
Run the Report and Return to Your TACL Prompt
To run a report and return to your TACL prompt, select Z:
Selection?z
SQL Conversational Interface - T9191D46 - (31MAR01)
COPYRIGHT HP COMPUTER CORPORATION 1987-2001
--- 30887 row(s) selected.
End of SQLCI Session
25>