XYGATE Merged Audit Reference Manual

Table Of Contents
XYGATE Merged Audit
®
Reference Manual
Appendix G: Data Mapping
XYPRO Technology Corporation 263 Proprietary and Confidential
EMS Note 4
The CLIENTPROGRAM column will be updated based on the value of the parameter
EMSSENDERPROCESSLOOKUP:
EMSSENDERPROCESSLOOKUP = None
The MOVER will not look up the client program so CLIENTPROGRAM will be
"NULL".
EMSSENDERPROCESSLOOKUP = ALL
The MOVER will look up the client program and update the column.
EMSSENDERPROCESSLOOKUP = LOCALONLY
If the system name in the process descriptor of the EMS message is the same as
the system name of the MOVER object file, the MOVER will look up the client
program and update the column.
EMS Note 5
If you are running H06.27 or greater or J06.16 or greater you will have an EMS
Collector named $ZCLA. This collector contains CLIM audit information. You must add
an EMS MOVER to read this Collector and make sure that you have a Filter Definition
in your FILTERS file to capture the data.
SSID = TANDEM.CIP.H03
Event-Number = 5239
EMS Audit Session Table
Column Type Record Contents
PARTITIONKEY
See General Note 1, pg 240.
numeric 4 MOVER Generated
RECORDSESSIONKEY timestamp MOVER Generated
RECORDINSTALLKEY timestamp MOVER Generated
SESSIONID char 36 ZEMS_TKN_XSENDERID_PD
FOUNDSESSIONSTART char 1
FOUNDSESSIONEND char 1
SESSIONNAME varchar 40
PROCESSTHREADID varchar 50 ZEMS_TKN_XSENDERID_PD
PROCESSTHREADID2 varchar 50 ZEMS_TKN_XSENDERID
CLIENTPROGRAM varchar 50
See EMS Note 4.
ANCESTORPROCESSTHREADID varchar 50
IPADDRV46 char 46
DNSNAME varchar 100
CLIENTCURRDIR varchar 200