XYGATE User Authentication Reference Manual
XYGATE
®
 User Authentication
™
 (XUA) 1.85 Reference Manual 
Chapter 16. What-if Testing 
XYPRO Technology Corporation  161  Proprietary and Confidential 
REPEAT <count>   Repeats a command 
TIME <dd[mm[yyyy]],hh :mm]> 
     Time entered will be simulated. 
     Example : TIME 01012010,09 :00 (January 1, 2010) 
TIME      Returns to actual time. 
USERAUTH    Toggles the program between using a call to 
     user_authenticate_ and the internal program logic 
     for EXPLAIN testing. 
] 
Access check: 
16.13.9  H or HISTORY 
This command is used to display your previous commands. To display a specific 
number of commands, enter a number in the command following HISTORY. 
Example 10: How to display the session history of your What-if commands 
Access check:H 
1 LOGON UATEST.TEST001 * UATEST.TEST002 
2 LOGON UATEST.TEST001 * alias:"uatst" 
3 LOGON UATST.TEST003 * UATST.TEST001 $SYSTEM.XYGATEAC.XYGATEAC * *  
4 LOGON UATST.TEST005 * 0,0 * $SYSTEM.ZTCPIP.LOGIN * 
5 LOGON UA.TEST003 * 0,0 * * 123.456.78.90 
6 LOGON UATST.TEST003 * 0,0 * * 123.456.78.90 NO DEFAULT 
Access check: 
16.13.10  IGNOREPASSWORD 
Syntax: 
IGNOREPASSWORD {ON | OFF} 
If set to ON, you do not have to enter a password when prompted during testing; 
simply press Enter to continue. 
If set to OFF, the default, you must enter the TO_USER’s password to complete the 
logon test. 
16.13.11  MONITOR 
This command causes XUA to generate a monitor dump for the What-if session.  
Note: Monitor dumps can be quite sizeable and should only be created under direction 
from XYPRO Technology. 
Syntax: 
MONITOR <output file> 
Example 11: How to generate a monitor dump for the What-if session 
$SYSTEM XYGATEUA 26> RUN XYGATEUA ACCESS 
XYGATEUA 1.70 (c) 1999-2010 XYPRO Technology Corporation XYPRO \XYS7000 20031231  
UACONF CHECKSUM 758712878 ($SYSTEM.XYGATEUA.UACONF) 