XYPRO Technology Corporation  189  Proprietary and Confidential 
To select the type of audit, select J. 
Example: 
Selection? J 
Do you want to include Test results (T), Production results (P) 
or Both (B) types of results: 
Type of results (T,P,B) <Both>? B 
19.5.10  Comment 
You may limit the report to only those audit entries with COMMENTs that contain the 
string you enter here. 
To select the COMMENTs you want included in the report, select K. 
Example: 
Selection?K 
Enter a portion of the User Authentication comment 
XUA Comment <*>? 
19.5.11  Delete Comments (Choose to Include Comments) 
To generate a shorter report, you may choose to suppress the COMMENT field in the 
report. Enter "Yes" or "No" (defaults to "Yes"). 
To suppress COMMENTS, select L. 
Example: 
Selection? L 
Do you want to suppress comments <Yes>?N 
19.5.12  Output File 
The XUA_REPORT macro puts a job in the spooler called $S.#XYGATE.USERAUTH. 
To change the spooler location, select M. 
Example: 
Selection? M 
Output file <$S.#XYGATE.OBJSEC>? $S.#HP1.LP 