XYGATE User Authentication Reference Manual

XYGATE
®
User Authentication
Reference Manual
Appendix C: XUA Macros
XYPRO Technology Corporation 300 Proprietary and Confidential
C8: XUA_EXPLAIN Macro
The XUA_EXPLAIN macro starts the XYGATEUA process in EXPLAIN mode, which
generates information about its rulings on logon requests including a list of the
UAGroups that were considered. It is the equivalent of typing RUN XYGATEUA
EXPLAIN. Refer to Chapter 16, “What-if Testing” starting on page 137 for instructions
on how to test XUA in those modes.
Example:
$SYSTEM.XYGATEUA 4> XUA_EXPLAIN
XYGATEUA 1.70 (c) 1999-2010 XYPRO Technology Corporation XYPRO Technology \SIMI
20091231
UACONF CHECKSUM 336940895 ($SYSTEM.XYGATEUA.UACONF)
UAACL CHECKSUM 1451102739 ($SYSTEM.XYGATEUA.UAACL)
Explain mode on
Safeguard Password May Change : 180 days before expiration
Safeguard Password History : 0
Safeguard Minimum Password Length : 0
Safeguard Password Required : Off
Safeguard Authenticate Maximum Attempts : 3
Safeguard Authenticate Fail Timeout : 60 seconds
Safeguard Authenticate Fail Freeze : Off
Safeguard Namelogon : On
Safeguard Blindlogon : On
Safeguard Password Expiry Grace : 30 days
Access check: