HP Officejet Pro X series - Printbar Install Guide
10
46
47
Print a print quality report. If there are problems, then follow the
Print Quality Checklist in the Troubleshooting Guide.
Open the Engineering menu.
X451
1. Press the Cancel
button.
2. Press the Back
button.
3. Press the Cancel
button twice.
X476/X551/X576
1. Touch the Home
button.
2. Touch the Back
button.
3. Touch the Home
button twice to enter the
Engineering menu.
48
49
Run the following tap tests:
• 10 tap
• 12 tap
• 61 tap
• 909 tap
1. Touch Manufacturing Menu.
2. Use the arrow key to nd the Reports Menu, and then touch
the OK button.
3. Use the arrow key to nd the Print-mech tap tests, and then
touch the OK button.
4. Use the arrow key to nd the tap test to run.
Interpret 10 tap test results (OOBE states)
1. The printed tap test results contain a sequence of numbers at line number 68, "Startup Complete," of the printed report.
2. Use the following table and gure to interpret these numbers.
Column Code Acceptable values
Column 1 DSID_PEN_PRINTER_STARTUP_BITS A value of 1 indicates that the printbar has been started up.
This means that shipping uid has been removed from the printbar and replaced with
ink. This is the expected state for a printer after initialization.
Column 2 DSID_OOBE_STATE 255–OOBE messaging complete.
Column 3 DSID_INK_SUPPLY_OOBE_COMPLETE 1–SHF purge is complete and service wipes have been enabled.
Column 4 DSID_CAL_OOBE_STATE A value of 2 means that the OOBE printed calibrations are complete.
A value of 1 means the OOBE printed calibrations are in progress.
A value of 0 means the OOBE printed calibration does not exist so no printing/
calibration for OOBE is attempted.
Column 5 DSID_IQ_LIST_INDEX A value of 1 means that pen height and beam center have been completed, and that
BDD is scheduled (or pending) to perform normally.
Column 6 DSID_BDD_FAIL_MASK 0–internal use only.
Column 7 DSID_IDS_FIRST_CHARGE_REQUIRED 0–internal use only.
Column 8 DSID_PRINTHEAD_CAL_NEEDED A value of 0 indicates that OOBE calibrations (not IQ calibrations) are complete. This is
so the messaging is complete for the calibrations. For example, if this value is 0, but
the CAL_OOBE_STATE=1, you will get the printed OOBE calibrations, but the control
panel may display Preparing instead of Calibrating.
45
Turn o the product, and then turn the product on. The product
will boot in user (standard) mode.
NOTE: Use the power button to turn the product o and on. If the
power button does not work, see the Troubleshooting guide.