HP OneView REST API Reference

connection-templates
connection-templates.html[10/17/2013 10:35:35 AM]
values for the status of the resource:Unknown - should be
avoided, but there may be rare occasions where status is
Unknown; OK - indicates normal/informational behavior; Disabled
- indicates that a resource is not operational; Warning - needs
attention soon; Critical - needs immediate attention.
type: string
category: description: Resource category used for authorizations and resource type
groupings
type: string
description: description: Brief description of the resource
type: string
created: description: Date and time when the resource was created
pattern: [1-2][0-9][0-9][0-9]-([0-1][0-9])-[0-3][0-9]T[0-2][0-9]:[0-5][0-9]:[0-5]
[0-9](.[0-9][0-9][0-9])?Z
type: string
format: YYYY-MM-DDThh:mm:ss.sssZ
uri: description: The canonical URI of the resource
type: string
eTag: description: Entity tag/version ID of the resource, the same value that is
returned in the ETag header on a GET of the resource
type: string
modified: description: Date and time when the resource was last modified
pattern: [1-2][0-9][0-9][0-9]-([0-1][0-9])-[0-3][0-9]T[0-2][0-9]:[0-5][0-9]:[0-5]
[0-9](.[0-9][0-9][0-9])?Z
type: string
format: YYYY-MM-DDThh:mm:ss.sssZ
bandwidth: description: The bandwidth assigned to the connection-template
required: true
type: object
Properties
typicalBandwidth: description: The typical bandwidth of a network
connection, expressed in Mbps
required: true
type: number
maximumBandwidth: description: The maximum bandwidth of a network
connection, expressed in Mbps. In
Flex10 Ethernet module (Bergstrom),
the maximum supported Ethernet
bandwidth is 10 Gbps; in FlexFabric
module (Sheppard), the maximum