HP OneView REST API Reference

events
events.html[10/17/2013 10:35:13 AM]
type: string
minLength: 0
maxLength: 255
rxTime: description: The source timestamp of an externally generated event such
as an SNMP trap or WBEM indication was received. The
format is an extended ISO 8601 String expressed as UTC
pattern: [1-2][0-9][0-9][0-9]-([0-1][0-9])-[0-3][0-9]T[0-2][0-9]:[0-5][0-9]:[0-
5][0-9](.[0-9][0-9][0-9])?Z
type: string
format: YYYY-MM-DDThh:mm:ss.sssZ
type: description: Identifies the resource type. This field must be set to
'EventResourceV2'.
type: string
urgency: description: The urgency attribute provides the level of urgency related to
the event. The following are the valid values for
urgency:None, Deferrable, Medium, High, Immediate,
Unknown. The urgency level is set to None by default
enum: None
Deferrable
Medium
High
Immediate
Unknown
type: string
required: true
severity: description: The severity of the event:Unknown - avoid using this value,
except on the rare occasions when severity is genuinely not
known. OK - indicates normal/informational behavior.
Disabled - not a valid severity for an Event and will be
obsoleted. Warning - needs attention soon. Critical - needs
immediate attention.
enum: Unknown
OK
Disabled
Warning
Critical
type: string
required: true
total: description: The total number of resources that would be returned from the query (including any
filters), without pagination or enforced resource limits
type: integer
type: description: Identifies the resource type. This field must be set to 'EventResourceCollectionV2'.
type: string