HP OneView 1.05 Release Notes

3 Troubleshooting
Use the following information to troubleshoot issues you might experience when using HP OneView.
Table 1 Troubleshooting: Issues and resolutions
ResolutionIssue
Press the F5 key to refresh the browser window.Browser is not responding or is not displaying expected
content.
Set the date and time on the hypervisor hosting the HP
OneView virtual machine.
Superblock last mount time (<date>) is in the
future during appliance boot.
Remove the enclosure with the force option selected, then
add it again.
Add enclosure completes but interconnects display
AddedWithErrors state.
Add the enclosure again.Add enclosure fails with multiple error codes.
If you did not make any hardware changes to the servers
in the enclosure, edit the affected server profiles and
All server profiles within an enclosure show this error
message after the enclosure was reset: The server
reapply them to the server blades in the enclosure (the
hardware associated with this profile has
server profiles that were originally applied are still assigned
to the servers).
been reinserted into the expected enclosure
bay. The server profile needs to be
reapplied to the server hardware.
Refresh the enclosure again.Enclosure refresh operation encounters an error, such as
Unable to configure interconnect, since it
is no longer managed by this appliance.
Refresh the enclosure.When server blades are added or removed from an
enclosure, the power utilization metrics displayed on the
Enclosure screen do not reflect the change to the maximum
power consumption for the enclosure.
Refresh the enclosure.Interconnect stays in the imported state for a long time after
a firmware upgrade
Refresh the enclosure and ignore the alert (interconnect
firmware version has not changed for HP OneView 1.05).
Logical Interconnects screen displays an alert indicating
that one or more interconnects are not at the correct
firmware level after upgrading from HP OneView 1.0 or
1.01 to HP OneView 1.05.
Perform Reapply configuration action from the Logical
Interconnects screen.
Interconnect reports ConfigError state.
Change a different setting on the Logical Interconnect
Group to trigger the consistency check, and then use the
Logical Interconnects are not flagged as Inconsistent with
Group after changing only the native setting on a network
in an uplink set for the Logical Interconnect Group. Update from group action on the Logical Interconnect
screen.
Click the shield icon in the right- side of the Chrome
browser address bar, and click the link to load the remote
console.
Launch console action does nothing in the Google Chrome
browser
Unassign the server profile, wait for the unassign operation
to complete, then re-assign to server hardware. This
Server profile is in an error state that is not resolved by
following provided resolutions in the HP OneView UI.
preserves any virtual identifiers and ensures that the profile
is completely re-applied to the target system.
If the specified BIOS settings are not supported by the
server, reset the BIOS settings to the default value in the
server profile and re-apply the profile.
Server profile unable to apply one or more BIOS settings.
Delete the connection and add a new one with the correct
MAC or WWN.
Unable to deploy connection due to malformed user-defined
MAC or WWN
Ensure that a virtual ID pool exists and is enabled or
recreate the server profile with physical IDs.
Unable to add connection to existing profile if virtual ID
pool is disabled.
9