FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
31SNMP Reference for Directors and Edge Switches
FA MIB Sensor Trap
This trap is generated whenever a status change occurs for a fan or power supply
FRU. There is one variable binding.
FA MIB Port Status Change Trap
This trap occurs whenever a port status change occurs. There are two variable
bindings.
Example
Interpretation of trap information from HP OpenView
The output from HP OpenView for a series of traps is shown below:
- Minor Thu May 02 09:29:30 10.235.4.111 NO
TRAPD.CONF FMT FOR .1.3.6.1.2.1.8888.0.1 ARGS(2):
[1]
mgmt.mib-2.fcMgmtMIB.fcMgmtObjects.fcMgmtConfig.fcC
onnUnitTable.fcConnUnitEntry.fcConnUnitStatus.3.2.0
.0.0.0.0.0.0.0.0.0.0.0.0.0 (Integer): ok [2]
Binding OID Value
1 1.3.6.1.2.1.8888.1.1.5.1.3.<unit-id>.<sensor-index>
fcConnUnitSensorStatus.<unit-id>.<sensor-index>
Where unit-id is the WWN of the switch with 8 zeros
appended for a total length of 16. Example:
1.2.3.4.5.6.7.8.0.0.0.0.0.0.0.0
And where sensor-index refers to the FRU in the sensor
table which has changed state. For example if
sensor-index was 5, then you could look at the 5
th
entry
in the sensor table to determine which FRU was affected.
See description for
FcConnUnitSensorStatus
on page 98.
Binding OID Value
1 1.3.6.1.2.1.8888.1.1.6.1.6.<port-index>
fcConnUnitPortStatus.<port-index>
Where port-index is the port number
normalized to the range 1-140.
See definition for
FcConnUnitPortStatus” on page 103.
2 1.3.6.1.2.1.8888.1.1.6.1.5.<port-index>
fcConnUnitPortState.<port-index>
Where port-index is the port number
normalized to the range 1-140.
See definition for
FcConnUnitPortStatus” on page 103.