FW 05.01.00 and SW 07.01.00 HP StorageWorks SNMP Reference for Directors and Edge Switches Reference Guide (AA-RQ7BD-TE, June 2003)

SNMP Support
79SNMP Reference for Directors and Edge Switches
FxPort Error Table
A table that contains one entry for each FxPort, counters that record the numbers
of errors detected.
Fabric
Element MIB
Object
Name
Type
Provided
By
Access Description
fcFxPortErrorF
xPortIndex
FcFeFxPortInd
ex
SNMP R This object identifies the FxPort within the
module. This number ranges from 1 to the
value of fcFeModulePortCapacity for the
associated module. The value remains
constant for the identified FxPort until the
module is re-initialized.
This number ranges from 1 to
AS_glob.prod_cnfg_ptr->ports_per_modul
e.
FcFxPortLinkF
ailures
Counter PSCC R The number of link failures detected by this
FxPort.
FcFxPortSyncL
osses
Counter PSCC R The number of losses of synchronization
detected by the FxPort.
FcFxPortSigLo
sses
Counter PSCC R The number of losses of signal detected by
the FxPort.
FcFxPortPrimS
eqProtoErrors
Counter PSCC R The number of primitive sequence protocol
errors detected by the FxPort.
FcFxPortInvali
dTxWords
Counter PSCC R The number of invalid transmission words
detected by the FxPort.
FcFxPortInvali
dCrcs
Counter PSCC R The number of invalid CRCs detected by the
FxPort.
FcFxPortDelim
iterErrors
Counter PSCC R The number of Delimiter Errors detected by
this FxPort.
FcFxPortAddr
essIdErrors
Counter PSCC R The number of address identifier errors
detected by this FxPort.
FcFxPortLinkR
esetIns
Counter PSCC R The number of Link Reset Protocol received
by this FxPort from the attached NxPort.