HP StoreVirtual 4630 Storage Maintenance Guide (AX696-96343, December 2013)

To re-image the storage blades, perform the steps in the following sections for each blade.
Verify minimum server requirements
1. Log in to iLO for the storage blade.
2. Boot the storage blade from the DVD.
3. Select the F10 Intelligent Provisioning option after the RAID controller BIOS initialization.
4. Select a language.
5. Accept the HP End User License Agreement.
6. Select Maintenance.
7. Select HP Insight Diagnostics.
8. On the System Survey tab, verify that the specified items in the Overview category (default)
meet the minimum requirements listed in Table 2 (page 16).
CAUTION: If any items do not meet the requirements listed in Table 2 (page 16) and Table 3
(page 16), do not continue with this procedure.
Table 2 Minimum requirements, overview category
Minimum requirementItem
Intel Xeon Processor E5-2620 @ 2.00GHzCPU on the storage blade
27 hard drives, which include the following:Type and number of drives
Slot 2: 25 drives on the HP Smart Array P721m
controller
Slot 0: 2 drives on the HP Smart Array P220i
controller
64 GBMemory
HP FlexFabric 10Gb 2-port 554FLB Adapter (appears
as OneConnect 10Gb NIC (be3) in the CMC)
NIC
9. From the Categories list, select Storage.
10. Verify that the specified item meets the minimum requirements listed in Table 3 (page 16).
Table 3 Minimum requirements, storage category
Minimum requirementItem
Array Controller in Slot 0: HP Smart Array P220i
controller
Model: HP P220i
Firmware: 3.60 or later
Installed Memory: 512 MB
Battery/Capacitor Present: Yes
BIOS boot device order: 1
Array Controller in Slot 2: HP Smart Array P721m
controller
Model: HP P721m
Firmware: 3.60 or later
Installed Memory: 2 GB
Battery/Capacitor Present: Yes
BIOS boot device order: 2
Run server diagnostics
1. On the HP Insight Diagnostics Test tab, select Quick Test and specify the number of loops.
16 Maintaining the HP 4630 system