HP StoreVirtual 4630 Storage Maintenance Guide (AX696-96343, December 2013)

2. Click Begin Testing.
The Survey Tab displays the data from the tests.
Wait for the tests to finish, which may take several minutes.
3. When the tests have completed, select the Log tab and check the failure log to see if the Quick
Test reports any failures.
4. If the Quick Test reports any errors, fix all errors before continuing.
If you need more information about an error, run a Complete Test on any component that
reported a failure.
If you want to run only specific tests, use the Custom Test option.
For assistance with the Complete or Custom Test options, contact HP technical support.
5. Click Exit Diagnostics.
6. Reboot the server.
7. Image the LeftHand OS software.
Image the LeftHand OS software
IMPORTANT: If the storage blade accidentally power-cycles during the LeftHand OS software
imaging process, you cannot successfully resume or restart the imaging. You must begin with
“Re-imaging the storage blade with the LeftHand OS software” (page 15).
1. Log in to iLO for the storage blades.
2. Mount the HP StoreVirtual Quick Restore .iso using Virtual Mount.
3. When prompted, insert the USB flash drive containing the license key file.
NOTE: Use the iLO dongle (delivered with the c7000 enclosure) to connect the USB flash
drive so that you can plug in the USB key.
4. When prompted to identify the OS version to install, enter Y.
IMPORTANT: Manually entering the license key
If the installer program cannot find a properly formatted license key on the USB flash drive,
you will be given the chance to enter in the license key.
Enter the license key if prompted. You have three attempts to correctly enter a valid HP license
key. If all three attempts are unsuccessful, restart the process with Step 1.
5. Finish the LeftHand OS software imaging.
Finish the LeftHand OS software imaging
The imaging process starts and displays the Auto Imaging Done message when complete.
1. Disconnect the Virtual Media using iLO.
2. Remove the USB flash drive from the dongle.
3. Reboot the storage blades.
4. Enter start to log into the storage blade.
NOTE: After field recovery, the storage server will not boot properly if a properly configured
zone is not assigned. If the start prompt does not display within 15-20 minutes, do the following:
1. Power down the storage blades.
2. Using Virtual SAS Manager, verify the zone configuration and blade bay assignment.
3. Power on the storage blades.
5. Navigate to Network TCP/IP Settings.
Performing field system recovery of the HP 4630 storage system 17