HP StorageWorks disk enclosure fan interconnect board replacement instructions (504222-001, September 2009)

8. Partially remove the fan module from the enclosure.
a. Lift up on the mounting latch (1).
b. Position one hand under the module, and with the other hand,
pull the module out of the enclosure (2).
9. Disconnect the Rear Power UID ribbon cable (1) and fan interconnect
cable (2) from the backplane, loosen the retaining screw holding
the interconnect board to the chassis (3), and then, lift the
interconnect board up and out of the chassis (4).
Installing a fan interconnect board
1. Seat the interconnect board in the chassis (1) from the backplane,
tighten the retaining screw holding the interconnect board to the
chassis (2) connect the fan interconnect cable (3), and connect the
Read Power UID ribbon cable (4).
2. Reinstall the fan module.
a. Insert the module into the enclosure opening.
b. Push the fan module into the enclosure until a click is detected
when fully seated.
Page 3