HP StorageWorks P9000 Cluster Extension Software Administrator Guide (TB534-96009, February 2011)

Description A space-separated list of RAID Manager instances that P9000 Cluster Extension can
use to communicate with the disk array. The instance numbers must be the same
among all cluster systems. P9000 Cluster Extension can alternate between the
specified instances.
VCS
This object is a string-vector element. Add a new element to the list for each system
name.
Files Linux/UNIX
/etc/horcmX.conf
Windows
%systemroot%\horcmX.conf
where X is the RAID Manager instance number.
ResyncMonitor
Format String
Description (Optional) Starts the pair/resync monitor to monitor the disk pair status and
resynchronize disk pairs if the ResyncMonitorAutoRecover attribute is set to YES.
Valid values YES
NO (default)
ResyncMonitorAutoRecover
Format String
Description (Optional) Automatically recovers disk pairs states if the disk pairs are monitored
by the pair/resync monitor.
Valid values YES
NO (default)
ResyncMonitorInterval
Format Integer
Description (Optional) Specifies the monitor interval (in seconds) that the pair/resync monitor
checks the disk pair status.
Default
value
60
ResyncWaitTimeout
Format Integer
Description (Optional) Specifies the timeout value (in seconds) for a disk pair resynchronization.
It may take some time to resynchronize disks. The timer times out if there is no change
in the percentage value of the copy status for the device/copy group in the specified
time interval. The timeout value is used if the ApplicationStartup object is set to
RESYNCWAIT.
Default
value
90
APPLICATION objects 91