Table 1 Windows remote installation error codes (continued)
Corrective actionDescriptionERROR code
Remove all Cluster Extension XP-type
resource(s) from this cluster, and then
run the P9000 Cluster Extension setup.
Uninstall failed on the local cluster
node.
Setup is unable to remove the Cluster
Extension XP resource type. Cluster
Extension XP resource(s) are still
configured in this cluster.
ERROR_RESOURCE_EXISTS
Remove all Cluster Extension XP-type
resource(s) from this cluster, and then
run the P9000 Cluster Extension setup.
Uninstall failed on the local cluster
node.
A Cluster Extension XP resource is still
online.
ERROR_RESOURCE_STATE_ONLINE
Unregister the resource extension DLL
by running the following cluster
command: Cluster
/unregadminext:clxmscsex.dll
Uninstall failed on the local cluster
node.
Setup was unable to unregister the
P9000 Cluster Extension extension DLL.
ERROR_CLXMSCSEX_UNREGISTER_FAILED
Delete the file clxpcf from
INSTALL_DIR\bin.
Uninstall completed on the local cluster
node.
Setup was unable to delete the PCF file.
ERROR_PCF_REMOVAL_FAILED
Remove the environment variable
HPCLX_PATH from the local cluster
node.
Uninstall completed on the local cluster
node.
Could not unset the path variables.
CLXUNSETPATH_FAILED
Delete the clxeventlog.dll from
the following registry entry:
HKEY_LOCAL_MACHINE\SOFTWARE\
Microsoft\Windows\
CurrentVersion\SharedDlls
Uninstall completed on the local cluster
node.
Could not delete clxeventlog.dll
from the following registry entry:
HKEY_LOCAL_MACHINE\SOFTWARE\
Microsoft\Windows\
CurrentVersion\SharedDlls
ERROR_DELETE_EVENTLOG_DLL_FAILED
Delete clxmscs.dll and
clxmscsex.dll from the following
registry entry:
HKEY_LOCAL_MACHINE\SOFTWARE\
Microsoft\Windows\
CurrentVersion\SharedDlls
Uninstall completed on the local cluster
node.
Could not delete clxmscs.dll and
clxmscsex.dll from the following
registry entry:
HKEY_LOCAL_MACHINE\SOFTWARE\
Microsoft\Windows\
CurrentVersion\SharedDlls
ERROR_UNINSTALL_DRS_FILES_FAILED
If cluster installation fails with the message Could not get the system drive for the
cluster node or Setup was unable to run the installation in remote machine,
check whether the WMI service is running. To use the P9000 Cluster Extension cluster-wide
installation feature, the WMI service must be running.
Log files
The clxcfg.txt log file helps you locate and identify installation problems.
The following sample %WINDIR%\clxcfg.txt file shows the successful installation of P9000
Cluster Extension on an IA-64 server:
2008-04-09_142055: *****************************************
2008-04-09_142055: HP P9000 Cluster Extension setup started.
2008-04-09_142055: *****************************************
2008-04-09_142058: Please exit from all Cluster Administrator programs.
2008-04-09_142108: P9000 Cluster Extension version 5.00.00 Installation:
18 Installing P9000 Cluster Extension Software for Windows