HP XP7 Business Continuity Manager Messages (TK954-96003)
Table 64 Details of error codes DBxx – E8xx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair cannot be
made for one of the following
reasons:
E8A2
• The serial number of the
storage system specified for
the S-VOL is incorrect.
• Another path group ID is
already assigned for the
specified journal group.
Not outputOutputNot outputA resynchronization that
reverses the copy direction for
E8A6
CAJ copy pairs cannot be
performed because the journal
group of the specified volume
is not registered in the storage
system.
Not outputOutputNot outputA resynchronization that
reverses the copy direction for
E8A7
CAJ copy pairs cannot be
performed because a journal
volume is not registered in the
storage system for the journal
group of the specified volume.
Not outputOutputNot outputThe specified copy pair cannot
be suspended because it is not
E8A8
a CAJ copy pair, or the P-VOL
and S-VOL for journal group
do not match.
Not outputOutputNot outputA CAJ copy pair cannot be
suspended because the storage
system is being turned on.
E8A9
Not outputOutputNot outputA delta resync pair cannot be
made because the mirror ID of
E8B6
the specified R-JNL group is
used by another CAJ copy
pair.
Not outputOutputNot outputA delta resync pair cannot be
made because the specified
E8B9
journal group is registered to
EXCTG.
Not outputOutputNot outputRegistration to EXCTG has
failed because the mirror ID is
E8BB
different from the registered
mirror ID.
Not outputOutputNot outputRegistration to EXCTG has
failed because the number of
E8BD
journal groups to be registered
exceeded the maximum
number which can be
registered.
Not outputOutputNot outputRegistration to EXCTG has
failed because the number of
E8BF
subordinate storage systems
has exceeded the maximum
Details of error codes 243