HP XP7 Business Continuity Manager Reference Guide (TK954-96004)
Table 77 Contents of the Volume Query Information (CAA) Panel (continued)
DescriptionItem
• MM: The minute is
displayed.
• SS.NNNNNN: The
second is displayed.
Consistency timeConsistency Time (GMT)
• On the first line:
(GMT):consistency-
time-in-GMT
• On the second line:
(LOCAL):consistency-
time-in-GMT
If the consistency time is
invalid, N/A is displayed.
Consistency group IDC/T ID
Error level
3
ERROR LVL
• VOLUME: When a failure
occurs, only the affected
volumes are suspended.
• GROUP: When a failure
occurs, all volumes in the
same copy group are
suspended.
C/T group timer type
3
TIMER TYPE
• SYSTEM: Uses a
timestamp to maintain
consistency.
• LOCAL: Uses the storage
system's internal clock to
maintain consistency.
• NONE: Does not maintain
consistency.
Write-protect for the S-VOL
3
PROT MODE
• PROTECT: Update of the
S-VOL is prohibited after
the copy pair is
suspended (YKSUSPND
command is executed).
• PERMIT: Update of the
S-VOL is allowed after the
copy pair is suspended
(YKSUSPND command is
executed).
Pace of copying
3,
COPY PACE
• NORMAL: The speed of
the copy operation
improves. However,
update I/O load on
P-VOL is high, and this
140 ISPF panels