HP XP7 Business Continuity Manager Reference Guide (TK954-96004)
YKLCNS2 = N/A (&YKLCNS2 = N/A )
LOGPUT = N/A (&YKLOGPT = N/A )
SYSLOG = N/A (&YKSYSLG = N/A )
YKZ371I YKENV command return code=0.
YKERCODE Command
Format
YKERCODE
1
error-code
Function
This is a TSO/E command.
This command displays the details of a specified error code on the TSO/E terminal.
The command displays the following information:
• Error details:details-of-error
Displays the error details.
• Type of error:cause-of-error
Displays the cause of the error. Possible choices are: BC, CA, CAA, CAJ, CMD (command
device), PATH (logical path), or Others (other).
Parameters
error-code ~ <4 hexadecimal characters>
Specify the storage system sense byte information (error code) that is included in the message
displayed by Business Continuity Manager. For details on error codes, see the section that describes
storage system sense byte information in the HP XP7 for Business Continuity Manager Messages.
Example
The following shows an example of executing the YKERCODE command.
READY
YKERCODE 6A13
Error details:
The command could not be executed because a remote command was executed
while the command device was not defined.
Type of error:
Others.
Return codes
Table 107 (page 202) lists the return codes that are returned when the YKERCODE command
terminates.
Table 107 YKERCODE Command Return Code List
MeaningReturn Code
The command completed normally.0
No description of the specified error code was found.8
Command execution terminated because of an invalid parameter.16
The module cannot be loaded. Possible causes are as follows:64
• The library dataset has not been linked.
• The module is protected by the RACF program control function.
202 CLI Commands