HP XP7 Business Continuity Manager Reference Guide (TK954-96004)
NOINVALIDCHECK
Processing continues even when the status changes to anything other than the status specified by
the GOTO parameter (invalid statuses). If this parameter is specified, and the status does not change
to that specified in the GOTO parameter, command processing will continue until the timeout time
specified in the TIMEOUT parameter is reached.
The invalid statuses in Table 108 (page 205) differ depending on the value specified in the GOTO
parameter. The table shows an invalid status for each value specifiable in the GOTO parameter.
Table 108 Invalid Status for Each Value Specifiable in the GOTO Parameter
Invalid StatusesValue of GOTO Parameter
SIMPLEX, SUSPCU, SUSPER, TRANS, SUSPVS, HOLDER, NODELTA,
CONSLOST, or INVALID
DUPLEX
SIMPLEX, SUSPER, SUSPCU, HOLD, HOLDER, HOLDTRNS, NODELTA,
CONSLOST, or INVALID statuses.
SUSPEND
SUSPER, SUSPCU, HOLDER, CONSLOST, or INVALID statuses.SIMPLEX
SUSPER, SIMPLEX, SUSPCU, HOLD, HOLDER, HOLDTRNS, NODELTA,
CONSLOST, or INVALID statuses.
SUSPVS
SIMPLEX, SUSPER, SUSPCU, HOLDER, NODELTA, or INVALID statuses.HOLD
SIMPLEX, HOLD, HOLDER, HOLDTRNS, NODELTA, CONSLOST, or
INVALID statuses.
SWAPPING
When the command waits for copy pairs in the CG container specified by EXCTG ID to reach
DUPLEX status, it first waits for all journal groups in the CG container specified by EXCTG ID to
be registered in EXCTG. If an error is detected during EXCTG registration, the YKZ297E message
is output and the command terminates abnormally with return code 44.
When the command monitors the status of a copy pair in an BC copy group to which the CAJ
ATTIME suspend time has been set, the check operation differs depending on whether the
NOINVALIDCHECK parameter is specified:
• If the NOINVALIDCHECK parameter is not specified
The status of the CAJ copy pair at the time of BC copy pair suspension will be checked. If an
error is detected, the YKZ407E message, YKZ408E message, or YKZ409E message is output
and the command terminates abnormally with return code 24.
• If the NOINVALIDCHECK parameter is specified
The status of the CAJ copy pair at the time of BC copy pair suspension will not be checked.
DEVN(p-vol-device-number,s-vol-device-number) ~ <4-digit hexadecimal number, 4-digit
hexadecimal number>
Specify the device number of the copy pair (P-VOL and S-VOL) to operate.
Note that, for CG containers specified by EXCTG ID, the command checks the EXCTG registration
information for all CG containers.
After specifying the copy pair to operate, to view REXX variables (such as SimplexCt) shown in
information for copy pairs that are not operation targets, execute the YKQUERY command or
YKEWAIT command for all copy pairs.
TO({PRIMARY|SECONDARY})
Applies to Continuous Access Synchronous for Mainframe, Continuous Access Synchronous for
Mainframe with the HyperSwap attribute, Continuous Access Asynchronous for Mainframe, and
Continuous Access Journal for Mainframe.
Command details 205