BCM does not support a recovery procedure from failure in 4x4x4 Multi-Target configuration with
Delta Resync by misoperation. In this case, use the following assistance:
If you need to call technical support, make sure to provide as much information about the problem
as possible, including:
The circumstances surrounding the error or failure.
The content of any error messages displayed on the host systems.
The content of any error messages displayed on Remote Web Console.
The Remote Web Console configuration information (use the FD Dump Tool).
The service information messages (SIMs), including reference codes and severity levels,
displayed by Remote Web Console.
Do not specify the following values to the DADID of a Disk Configuration Definition, a copy group,
or a route list. Specifying those values may cause the information displayed in the Discover HP
Storage Arrays panel to become incorrect.
"R"
"CMD"
"I"
"K"
"RC"
Examples that cannot be specified:
"R"
"xx.R"
"R.xx"
"xx.R.xx"
where xx is an arbitrary string of one or more characters.
The YKWATCH command is not available for monitoring a copy pair status transition if the PPRCSUM
feature in DEVSUPxx is enabled in z/OS V1R13 or later. Use the YKEWAIT command to monitor
instead.
TLS 1.2 is not possible when HTTPS communicates with Replication Manager
Specification differences from previous versions
This section describes the specification differences between BCM version 7.6.0-00 and version 8.0.0-00.
In configuration files and in REXX variable structures, "XP7" is displayed as "VSPG1000".
Commands
New specification in version 8.0.0-00Specification in version 7.6.0-00Command
SMODEL({USP|USPV|VSP|VSPG1000})SMODEL({USP|USPV|VSP})YKQRYDEV
Specification differences from previous versions 11