HP XP7 Business Continuity Manager Release Notes (TK954-96001)
The amount of memory required to use BCM Monitor is shown as follows.
• For a user region less than 16 MB:
2,048 KB
• For an extended user region of 16 MB or more:
6,000 KB + (3 × number-of-copy-pairs) KB + (C + S) × 1 KB
C: Number of copy group parameters specified in the YKMONCG file.
S: Number of action parameters specified in the YKMONCG file.
Table 9 Disk space requirements
Number of directoriesRequired space (in unit of tracks)Files to be installed
515 tracksHPQSYSAMT
3090 tracksHPQSYLNKT
11 trackHPQSYLPAT
105 tracksHPQSYPRCT
1045 tracksHPQSYEXET
1045 tracksHPQSYEXVT
20060 tracksHPQSYPNLT
55 tracksHPQSYMSGT
55 tracksHPQSYTABT
Fixes
None.
Resolved issues
Resolved issues from 7.6.0-00 to 8.0.0-00
Table 10 Resolved issues
Applied OSApplied productsCorrected problems
All(Note)Business Continuity ManagerCorrected the problem in which the
program terminates abnormally with an
I/O error (YKZ257E) when the PATH
SMODEL is specified while YKQRYDEV
is executed. This problem occurs if the
following conditions are met:
1. The targeted volume (storage system)
in the command does not support
the path group ID.
• On Model XP12000/XP10000,
XP24000/XP2000
• On Model XP P9500 and on
micro version 70-05-00 or earlier
2. A path group ID x ‘01’ or more of
the DKC logical path is registered
between the targeted storage system
in the command and the storage
system specified in the SSN
parameter.
Fixes 7