Table 55 Required configuration files (3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration) (continued)
RemarksDescriptionItem
Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 2 and Remote 1 ->
Remote 2 Universal Replicator copy pairs
later time to include Cnt Ac-S Z copy
pairs.
Cnt Ac-J Z copy group between the primary site and remote
site 2
M-JNL number: Same value as the MJNL number between
the primary site and remote site 1
R-JNL number: Any value
Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 1 and Remote 1 ->
Remote 2 Universal Replicator copy pairs
Cnt Ac-J Z copy group between remote site 1 and remote
site 2
M-JNL number: Same value as the RJNL number between
the primary site and remote site 1
R-JNL number: Same value as the RJNL number between
the primary site and remote site 2
Mirror ID: A non-zero value that is different from the mirror
ID of any other Primary -> Remote 1 and Primary -> Remote
2 Cnt Ac-J Z copy pairs
This item is not necessary if you use
Remote Web Console to set up logical
paths.
A path set for inter-disk controller logical paths (bidirectional)
between the following sites is required:
Path set definition file
Primary site and remote site 1
Primary site and remote site 2
Remote site 1 and remote site 2
The following table describes the route list required for operation in a 3DC Multi-Target (Cnt Ac-J
Z x Cnt Ac-J Z) configuration.
Table 56 Required route list (3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration)
Required route listRemote site 2
state
Remote site 1
state
Primary site
state
Host on which Business
Continuity Manager is
started
Primary Remote 1UsableUsableUsablePrimary host
Primary Remote 2
Primary Remote 1UnusableUsableUsable
Primary Remote 2UsableUnusableUsable
Not requiredUnusableUnusableUsable
Remote 1 PrimaryUsableUsableUsableRemote host 1
Remote 1 Remote 2
Remote 1 PrimaryUnusableUsableUsable
Remote 1 Remote 2UsableUsableUnusable
Not requiredUnusableUsableUnusable
Remote 2 PrimaryUsableUsableUsableRemote host 2
Remote 2 Remote 1
Remote 2 PrimaryUsableUnusableUsable
Defining a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 191