HP XP7 Business Continuity Manager User Guide (TK954-96005)

Operating procedure during an intermediate site storage system failure (with
information lost from memory)
The following are the procedures that must be performed when a volatile failure occurs in the
intermediate site storage system.
Preparing
1. From the remote site, execute the YKRECVER command for the Continuous Access Journal Z
copy pair between the intermediate site and the remote site.
YKQUERY
YKRECVER
YKEWAIT GOTO(SIMPLEX) NOINVALIDCHECK
2. From the primary site, execute the YKMAKE command for the Continuous Access Journal Z
copy pair between the primary site and the remote site.
YKQUERY
YKMAKE
YKEWAIT GOTO(DUPLEX)
Operation in a 2DC configuration starts from the primary site.
362 Maintenance and troubleshooting operations