HP XP7 Performance for Open and Mainframe Systems User Guide (H6F56-96007)
Table 8 Performance management windows and monitoring data saved by the Export Tool
(continued)
Monitoring dataGUI operation
“Port statistics” (page 129)Select Fibre Port from Object list in Performance Objects
field in Monitor Performance window.
“Port statistics” (page 129)Select Mainframe Fibre Port from Object list in
Performance Objects field in Monitor Performance
window.
“Volumes (LU) statistics” (page 130)Select LUN Base from Object list in Performance Objects
field in Monitor Performance window.
“Remote copy operations by Cnt Ac-S and Cnt Ac-S Z (for
each volume (LU))” (page 133)
Select LUN (Cnt Ac-S/Cnt Ac-S Z) from Object list in
Performance Objects field in Monitor Performance
window.
“Remote copy by Cnt Ac-J and Cnt Ac-J Z (for each volume
(LU))” (page 136)
Select LUN (Cnt Ac-J/Cnt Ac-J Z) from Object list in
Performance Objects field in Monitor Performance
window.
“Host bus adapters connected to ports statistics” (page 130)Select WWN from Object list in Performance Objects
field in Monitor Performance window.
“All host bus adapters connected to ports” (page 131)
“Remote copy by Cnt Ac-J and Cnt Ac-J Z (at journals)”
(page 135)
Select Journal from Object list in Performance Objects
field in Monitor Performance window.
“Remote copy operations by Cnt Ac-S/Cnt Ac-S Z (whole
volumes)” (page 132)
Select Entire Storage System (Cnt Ac-S/Cnt Ac-S Z) from
Object list in Performance Objects field in Monitor
Performance window.
“Remote copy by Cnt Ac-J and Cnt Ac-J Z (whole volumes)”
(page 134)
Select Entire Storage System (Cnt Ac-J/Cnt Ac-J Z) from
Object list in Performance Objects field in Monitor
Performance window.
Resource usage and write-pending rate statistics
The following table shows the file names and types of information in the Monitor Performance
window that can be saved to files using the Export Tool. These files contain statistics about resource
usage and write pending rates.
Table 9 Files with resource usage and write pending rate statistics
Data saved in the fileCSV fileZIP file
Usage rates for parity groups in long range.PHY_Long_PG.csvPhyPG_dat.ZIP
Usage rates for parity groups in short range.PHY_Short_PG.csv
Usage rates for volumes in a parity group in long
range.
PHY_Long_LDEV_x-y.csvPhyLDEV_dat.ZIP
Usage rates for volumes in a parity group in short
range.
PHY_Short_LDEV_x-y.csv
Usage rates for Business Copy and Business Copy
Z volumes in a parity group in short range.
PHY_Short_LDEV_SI_x-y.csv
If external storage volumes are mapped to the volume
groups of HP XP7 Storage, this file includes the
PHY_ExG_Response.csvPhyExG_dat.ZIP
average response time for the volume groups
including external storage volumes (milliseconds).
If external storage volumes are mapped to the volume
groups of HP XP7 Storage, this file includes the
PHY_ExG_Trans.csv
amount of transferred data for volume groups
including external storage volumes (KB/sec).
Exported files 123