HP XP7 RAID Manager Installation and Configuration User Guide (T1610-96065)
Table Of Contents
- XP7 RAID Manager Installation and Configuration User Guide
- Contents
- 1 Installation requirements
- System requirements
- Supported environments
- Supported Business Copy environments
- Supported Continuous Access Synchronous environments
- Supported Continuous Access Asynchronous environments
- Supported Continuous Access Journal environments
- Supported Snapshot environments
- Supported Data Retention environments
- Supported Database Validator environments
- Supported guest OS for VM
- Supported IPv4, IPv6 platforms
- Requirements and restrictions for z/Linux
- Requirements and restrictions for VM
- Porting notice for OpenVMS
- Using RAID Manager with Hitachi and other storage systems
- 2 Installing and configuring RAID Manager
- 3 Upgrading RAID Manager
- 4 Removing RAID Manager
- 5 Troubleshooting
- 6 Support and other resources
- A Fibre-to-SCSI address conversion
- B Sample configuration definition files
- Glossary
- Index
Array. The same path ID must be specified between the site of P-VOL and S-VOL because the path
ID is used at the paircreate command.
(8)HORCM_ALLOW_INST
This parameter is used to restrict the users using the virtual command device. Allowing IP address
and port numbers are following.
For IPv4
HORCM_ALLOW_INST
#ip_address service
158.214.135.113 34000
158.214.135.114 34000
For IPv6
HORCM_ALLOW_INST
#ip_address service
fe80::209:6bff:febe:3c17 34000
Service in the above example means the initiator port number of HORCM.
If RAID Manager clients not defined HORCM_ALLOW_INST, HORCM instance starting up is
rejected by SCSI check condition (SKEY=0x05, ASX=0xfe) and RAID Manager cannot be started
up.
Examples of RAID Manager configurations
The following examples show RAID Manager configurations, the configuration definition file(s) for
each configuration, and examples of RAID Manager command use for each configuration.
Examples of RAID Manager configurations 67