HP XP7 RAID Manager Reference Guide (T1610-96064)

Syntax
raidcom get rcu [-rcu <serial#> <mcu#> <rcu#> -ssid <ssid> | -cu_free <serial#> <id> <pid>
Options and parameters
DescriptionOption
Specifies the CU specified by serial number, <mcu#>, <rcu#>. For XP7 Storage,
specify the number of which 300,000 is added to the serial number for <serial#>.
-rcu <serial#> <mcu#> <rcu#>
You can use hexadecimal numbers (add "0x" prefix) or decimal numbers for <mcu#>
and <rcu#>.
Specifies the subsystem ID.-ssid <ssid>
You can use hexadecimal numbers (add "0x" prefix) or decimal numbers for <ssid>.
Specifies the CU free specified by serial#, id#, pid# for setting MCU or RCU which
shows the information. For XP7 Storage, specify the number of which 300,000 is
added to the serial number for <serial#>.
[-cu_free <serial#><id><pid>]
< id > specifies the storage system type as follows:
For P9500 use R700.
For XP24000/XP20000 Disk Array use R600.
For XP12000 Disk Array/XP10000 Disk Array use R500.
For XP7 use R800.
< pid> specifies the path group ID (0-255).
Note:
The RCU registered by specifying "0" for <pid> is displayed its information
by default on the GUI of Continuous Access Synchronous, Continuous Access Journal,
or Continuous Access Journal Z.
Examples
Displaying RCU information.
# raidcom get rcu
Serial# ID PID MCU RCU M/R T STS MP NP IM FZ RTO(s) RTT(ms)
64034 R7 - 1C 23 RCU F NML 4 8 MR D 15 20
64034 R7 - 1C 23 RCU F NML 4 8 RO E 15 20
64034 R7 1 - - MCU E NML 4 8 - - 15 20
Description of each column in output example
Serial#: Product serial number.
For XP7 Storage, the number of which 300,000 is added to the serial number is displayed.
ID: Displays the ID for identifying RAID type: R7 = P9500, R6 = XP24000/XP20000 Disk Array,
R5 = XP12000 Disk Array/XP10000 Disk Array, R8 = XP7 Storage
PID: Displays a path group ID. If CU is specified for RCU, "-" is displayed.
MCU: Displays the CU number (hexadecimal) as MCU. If CU free is specified for RCU, "-" is
displayed.
RCU: Displays the CU number (hexadecimal) as RCU. If CU free is specified for RCU, "-" is
displayed.
M/R: Displays the CU type as MCU/RCU.
T: Displays the type of physical path, F:FIBRE, E:ESCON
STS: Displays the following status of the CU.
NML: Normal
WAR: Warning
196 Configuration setting commands