HP XP7 RAID Manager Reference Guide (T1610-96064)

ERR: Failing
UNK: Unknown, displayed when the target of the pair is MCU.
MP: Displays the number of path as minimum.
NP: Displays the number of path setting between MCU and RCU.
IM: Displays the incident mode setting to RCU.
MR: it sends incident to MCU host and RCU host
RO: it sends incident only to RCU host
If CU free is specified for RCU, "-" is displayed.
FZ: Displays the freeze option.
D: the freeze option is disabled.
E: the freeze option is enabled.
-: "-" is displayed when CU free is specified for RCU.
RTO (s): Displays the timeout value for RIO (Remote IO) setting between MCU and RCU.
RTT (ms): Displays the round trip time value between MCU and RCU.
# raidcom get rcu -cu_free 64034 R700 1
Serial# ID PID MCU RCU M/R T PNO MPORT RPORT STS_CD SSIDs
64034
R7 1 - - RCU F 1 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 2 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 3 CL1-A CL1-B NML_01 -
Description of each column in output example
-Serial#: Product serial number.
For XP7 Storage, the number of which 300,000 is added to the serial number is displayed.
-ID: Displays the ID for identifying RAID type: XP12000 Disk Array/XP10000 Disk Array :R5,
XP24000/XP20000 Disk Array : R6, P9500 : R7, XP7 Storage : R8
PID: Displays the path group ID. If CU is specified for RCU, "-" is displayed.
-MCU: Displays the CU number (hexadecimal) as MCU. If CU free is specified for RCU, "-" is
displayed.
-RCU: Displays the CU number (hexadecimal) as RCU. If CU free is specified for RCU, "-" is
displayed.
-M/R: Displays the CU type as MCU/RCU.
-T: Displays the type of physical path: F: FIBRE, E:ESCON.
-PNO: Displays the path number.
-MPORT: Displays the MCU port number.
-RPORT: Displays the RCU port number.
-STS_CD: Displays the following path status:
- NML_01: Normal
- ERR_02: Initialization failed
- ERR_03: Communication timeout
- ERR_04: Logical blockade
- ERR_05: Resource Shortage
- ERR_06: Serial Number Mismatch
- ERR_10: Invalid Port
raidcom get rcu 197