HP XP7 RAID Manager Reference Guide (T1610-96064)

DescriptionOption
(2) The option cannot be specified the device object name as follows:
D:\Vol(Dms,Dmt,Dmr)X\DskY,\Vol(Dms,Dmt,Dmr)X\DskY
(3) Sync executes the following behavior under any conditions:
If the logical drive which corresponds to a [-g <group>] is not open by any applications,
then sync flushes the system buffer to a drive and makes the dismount state for this drive.
If the logical drive which corresponds to a [-g <group>] is already opened by any
applications, then sync flushes only the system buffer to a drive. This is allowed to flush the
system buffer before pairsplit with mounting the PVOL (opening state), and indicates the
behavior as [FLUSH] below: [FLUSH] : ORA ORA_000[-] -> \Vol44\Dsk0 :
Volume{56e4954a-28d5-4824-a408-3ff9a6521e5d}
Returned values
--
Error codes
--
Examples
raidscan command examples for fibre-channel ports
# raidscan -p cl1-r
PORT#/ALPA/C,TID#,LU#Num(LDEV#...)P/S,Status,Fence,LDEV#,P-Seq#P-LDEV#
CL1-R/ ce/15,15, 7 5(100,101..)P-VOL PAIR NEVER 100,5678 200
CL1-R/ ce/15,15, 6 5(200,201..)SMPL ---- ---- ---- ---- -----
# raidscan -p cl1-r -f
PORT#/ALPA/C,TID#,LU#Num(LDEV#...)P/S,Status,Fence,LDEV#,Vol.Type
CL1-R/ ce/15,15, 7 5(100,101..)P-VOL PAIR NEVER 100,OPEN-3
CL1-R/ ce/15,15, 6 5(200,201..)SMPL ---- ---- ----OPEN-3
Example of -find option for raidscan
# ls /dev/rdsk/* | raidscan -findDEVICE_FILE UID S/F PORT TARG LUN SERIAL LDEV PRODUCT_ID
/dev/rdsk/c0t0d4 0 S CL1-M 0 4 31168 216 OPEN-3-CVS-CM
/dev/rdsk/c0t0d1 0 S CL1-M 0 1 31168 117 OPEN-3-CVS
/dev/rdsk/c1t0d1 - - CL1-M - - 31170 121 OPEN-3-CVS
Output of the raidscan command:
Port#, ALPA/C, TID#, LU#: port ID, arbitrated loop physical address, target ID, LUN.
For Business Copy, raidscan displays the MU# for each LUN (for example, LUN 7-0, 7-1, 7-2).
Num(LDEV#…): number of LDEVs and LDEV ID for a LUSE volume
P/S: volume attribute
Status: status of the paired volume
Fence: fence level (Continuous Access Synchronous only)
P-Seq#: serial # of the storage system which contains the partner volume of the pair
For XP7, the number of which 300,000 is added to the serial number is displayed.
P-LDEV#: LDEV number of the partner volume of the pair
Vol.Type: logical unit (LU) type (for example, OPEN-V, OPEN-9)
Group: group name (dev_group) as described in the configuration definition file
UID: Displays the unit ID for multiple storage system configuration. If UID appears as '-', the
command device for HORCM_CMD is not found.
S/F: Displays whether the port is SCSI or fibre
raidscan 73