R=E: 'R' flag can be changed to enable.
D: 'R' flag cannot be changed to enable.
W=E: 'W' flag can be changed to enable.
D: 'W' flag cannot be changed to enable.
S=E: 'S' flag can be changed to enable.
D: 'S' flag cannot be changed to enable.
R-Time: Displays the retention time for write protect, in units of day. The hyphen (-) shows that the
retention time is infinite. The application knows whether the target volume is denied to change to
writing enable by referring 'R-Time'.
Audit lock status is shown as the retention time plus 1000000. 'R-Time + 1000000' shows the
retention time with Audit lock status.
Example 5
Example of raidvchkscan command with -v pool option
# raidvchkscan -v pool -p CL2-d-0
PORT# /ALPA/C TID# LU# Seq# Num LDEV# Bsize Available Capacity
CL2-D-0 /e4/ 0 2 0 62500 1 160 2048 100000 1000000000
CL2-D-0 /e4/ 0 2 1 62500 1 161 2048 100000 1000000000
Output of the raidvchkscan command with -v pool option:
Bsize: Displays the data block size of the pool, in units of block (512 bytes).
Available(Bsize): Displays the available capacity for the volume data on the Snapshot pool in units
of Bsize.
Capacity(Bsize): Displays the total capacity in the Snapshot pool in units of Bsize.
Example 6
Example of raidvchkscan command with -v aou option ("aou" (allocation on use) refers to dynamic
provisioning)
# raidvchkscan -v aou -p CL2-d-0
PORT# /ALPA/C TID# LU# Seq# Num LDEV# Used(MB) LU_CAP(MB) U(%) T(%) PID
CL2-D-0 /e4/ 0 2 0 62500 1 160 20050 1100000 1 60 1
CL2-D-0 /e4/ 0 2 1 62500 1 161 200500 1100000 18 60 2
Output of the raidvchkscan command with -v aou option:
Used(MB): Displays the usage size the allocated block on this LUN. Range: 0 ≤ Used (MB) <
LU_CAP(MB) + 42MB
LU_CAP(MB): Displays the LUN capacity responded to the 'Readcapacity' command as SCSI
interface.
LU_CAP(BLK): Displays the LUN capacity (in block/512 bytes) responded to the 'Readcapacity'
command as SCSI interface.
U(%): Displays the usage rate of the allocated block on the Thin Provisioning pool containing this
LU.
T(%): Displays the threshold rate being set to the Thin Provisioning pool as high water mark.
PID: Displays the Thin Provisioning pool ID assigned to this Thin Provisioning volume.
raidvchkscan for Continuous Access Journal
The raidvchkscan command supports the (-v jnl [t] [unit#]) option to find the journal volume list. It
also displays any information for the journal volume.
Syntax
raidvchkscan { -h | -q | -z | -I[H][M][instance#] or I[TC][SI][instance#]| -v jnl [t] [unit#] | [ -s
<Seq#>] | [ -f[x] ] }
90 Data management commands