HP XP7 RAID Manager User Guide (T1610-96063)
Table 82 SSB codes returned by raidcom modify snapshot (continued)
raidcom modify snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The specified operation is not supported in the current
microcode version.
80002E3FExecutingCMDRJE
An internal error occurred. Call HP Technical Support.FEEC2EC6ExecutingCMDRJE
The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.
00022EF3ExecutingCMDRJE
Table 83 SSB codes returned by raidcom get snapshot
raidcom get snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
An internal error occurred. Call HP Technical Support.FEEC2EC5ExecutingCMDRJE
Table 84 SSB codes returned by raidcom delete snapshot
raidcom delete snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The value exceeds the range of LDEV number.00002E00ExecutingCMDRJE
The MU number exceeds the maximum.000B2E00ExecutingCMDRJE
The command ends abnormally because the volume out of
the range of LDEV number is specified as the P-VOL of a
Fast Snap or Snapshot pair.
00282E00ExecutingCMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
00332E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00342E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00352E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
00362E10ExecutingCMDRJE
The command ends abnormally because the Business Copy
pair is being resynchronized when the volume is shared
00492E10ExecutingCMDRJE
between the P-VOL of a Fast Snap/Snapshot pair and the
P-VOL of a Business Copy pair.
The command ends abnormally because the Business Copy
pair status is other than PSUS when the volume is shared
004A2E10ExecutingCMDRJE
between P-VOL of a Fast Snap/Snapshot pair and the
S-VOL of a Business Copy pair.
A Snapshot data cannot be obtained because the
Continuous Access Synchronous asynchronous pair status
004D2E10ExecutingCMDRJE
is other than PSUS or PSUE when the volume is shared
Error messages and error codes 271