Hitachi Global Link Manager Software Messages
Message ID Message Text Description
KAIE20703-E The log output destination
directory directoryName is not
writable.
Cause
The log output destination directory
(Device-Manager-agent-installation-
directory/agent/logs) is read-only.
Action
Make the log output destination
directory writable.
KAIE20704-E An I/O error occurred during
processing of the log settings.
Cause
An attempt to access the log property
file (Device-Manager-agent-
installation-directory/agent/config/
logger.properties) has failed.
Possible causes are:
• The file does not exist.
• The user has the file open.
• The user lacks access permissions.
• The settings are invalid.
Action
• Make sure that the
logger.properties file exists.
• If the logger.properties file is
open, close it.
• Grant access permissions for the
logger.properties file, or
change to a user who has access
permissions and restart the
service.
• Check the settings of the
logger.properties file. If they
are invalid, correct them.
KAIE20705-E The directory of the same
name as log output directory
exist. (file path = filePath)
Cause
The log output file cannot be created.
A directory which has the same name
as a log output file (below) exists in
the log output destination directory.
• Device-Manager-agent-
installation-directory/agent/logs/
trace.log
• Device-Manager-agent-
installation-directory/agent/logs/
access.log
• Device-Manager-agent-
installation-directory/agent/logs/
error.log
• Device-Manager-agent-
installation-directory/agent/logs/
service.log
Action
Messages with IDs Beginning with KAIE
3-7
Hitachi Global Link Manager Messages