HP XP7 Business Continuity Manager Messages (TK954-96003)

Table 57 Details of error codes 8Dxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
The S-VOL is in the Pending
status.
The status is invalid.
The status of the copy pair is
being changed.
Not outputOutputA BC copy pair cannot be
suspended. Possible reasons
8D2A
include one or more of the
following:
The status of the copy pair
does not allow the status
transition. For details, see error
code 2310.
The copy pair is in the
SIMPLEX status.
The copy pair is in the Split
status.
The specified C/T group ID is
not registered.
OutputNot
output
OutputNot outputThe serial numbers for the primary
and the secondary storage
8D2C
systems in the host command
parameter is incorrect.
OutputNot outputThe host command parameter is
incorrect.
8D30
Not outputOutputMultiple BC copy pairs cannot be
suspended because there is a
8D31
copy pair that does not allow the
status transition in the specified
copy pairs.
Not outputOutputNot outputThe command could not be
executed because the specified
8D38
volume is not in the SIMPLEX
status.
Not outputOutputNot outputA command device cannot be
defined because it differs from the
APID that was already registered.
8D39
Not outputOutputNot outputA command device cannot be
defined because the specified
APID is in use by another DEV.
8D3A
Not outputOutputNot outputA command device cannot be
deleted because the specified
volume is not a command device.
8D3D
Not outputOutputNot outputA command device cannot be
made because the specified CU
number is not supported.
8D3E
Not outputOutputNot outputThe command cannot be executed
because the volume specified as
8D41
the command device is already
part of a copy pair, or is a journal
volume.
Details of error codes 213