HP XP7 Business Continuity Manager Messages (TK954-96003)
Table 65 Details of error codes EAxx (continued)
Type of errorError detailsError
code
OthersTHPzPATHCMDCAJCAACABC
Not outputOutputNot outputA CAJ copy pair between the
intermediate site and the
EA46
remote site cannot be deleted
or suspended because the
journal group of the CAJ copy
pair between the primary site
and the intermediate site in a
3DC Cascade (CAJxCAJ)
configuration is in the
Active status.
Not outputOutputNot outputThe CAJ copy pair cannot be
suspended because it is a
delta resync pair.
EA4D
Not outputOutputNot outputThe status cannot be changed
from error status to the delta
EA89
resync preparatory status,
because the specified P-VOL
is not in HOLDER status.
Not outputOutputNot outputThe status of a CAJ copy pair
cannot be changed because
EA8A
the primary storage system is
currently being turned on or
turned off.
Not outputOutputNot outputA copy pair cannot be
created because the pool of
EA95
the THPz volume specified for
the P-VOL of a CAJ copy pair
is being initialized.
Not outputOutputNot outputThe CAJ copy pair cannot be
operated for each EXCTG
EAA0
because of the following
reasons:
• The JNLG specified in the
copy group is not
registered in the EXCTG.
• There is a copy pair with
a status that is TRANS.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EAA2
limit of CAJ in the MCU has
been exceeded. Check the
license capacity of this and
all related program products.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EAA3
limit of CA in the RCU has
been exceeded. Check the
license capacity of this and
all related program products.
Not outputOutputNot outputA CAJ copy pair cannot be
made because the charging
EAA5
limit of CAJ in the RCU has
been exceeded. Check the
Details of error codes 247